Quantcast
Channel: New Pharmacy Interview Questions :: ALLInterview.com
Browsing all 41 articles
Browse latest View live

what is difference between uniformity of content and content uniform

View Article



if calibration of 12 bowl dissolution apparatus does not meet a sing

View Article

what is capacity factor

Capacity factor is how much analyte in the sample is retained with respect to unretained material. Capacity Factor is calculated using following formula: RT1-RT0 Capacity factor= ---------- R0 Where, R

View Article

if calibration of 12 bowl of dissolution apparatus does not meet a s

View Article

what do you mean by end capping

A column is said to be endcapped when a small silylating agent (e.g., trimethylchlorosilane) is used to bond residual silanol groups on a packing surface.

View Article


what is the wavelength of polarimeter lamp

589.3 nm

View Article

what type of column are used in GC

golay column or capillary column. suppourt coated open tubular column

View Article

what is stationary phase

In Chemistry, the substance or material which doesn't change its physique or state in accordance with the Changes that occurred in surroundings. Generally, there are three phases that possessed by...

View Article


what are the limit of LOD and LOQ

limit of LOD: SIGNAL/ NOISE RATIO= 3. limit of LOQ: SIGNAL/NOISE RATIO=10

View Article


how quantitative stability is done

View Article

what is difference between vacuum pressure and vapor pressure

View Article

what is difference between uv , pda & ri detector ?

In UV it shows the detector response (peak/s) only at the programmable wavenength only with two dimentional view. In case of PDA detector the detector response shows at variable wavelengths in UV...

View Article

there are how many leak sensor in shimandzu hplc,agilent hplc,dionex

I think for water's HPLC there are 3 leak sensors and for shimandzu there are only 2.

View Article


HOW TO SELECT HPLC COLUMN FOR PARTICULAR PRODUCT.

based on the sample

View Article

why we are selecting dissolution media 900ml

View Article


what is purpose of slow,medium,fast sampling in process validation ?

View Article

Why Naphalene only used in calibration of HPLC

View Article


In dissolution test why sample is withdrawn from top of the paddle a

View Article

In dissolution test why sample is withdrawn from top of the paddle a

View Article

What is mean by partical size distribution.

View Article